This paper identifies the inherent strengths/weaknesses of rigid timber-framed partitions and quantifies the onset drifts for different damage thresholds under a unidirectional quasi-static cyclic loading. It reports
construction and testing of a multi-winged timber-framed partition wall specimen, with details typical of New Zealand construction practice.